About Terminal Server, Citrix, Delphi and other stuff
16 Oct
As you may have read I am currently implementing VMWare vSphere 4 on several HP Proliant DL380 G7 machines.
I ran across an interesting knowledge base article from VMWare that describes a possible issue that is summarized as “Power on and storage operations are slow with the HP Smart Array P410i controller“.
Essentially this just means a performance issue and the resolution is to install an extra (256 MB) cache module on the RAID controller.
The Cache Module has HP article # 462968-B21 (not to be confused with 462969-B21 which is the Battery Kit).
Google search on 462968-B21.
Related posts:
Active Directory Altiris Automation Manager bug Citrix Dell Delphi Exchange Exchange2003 Exchange2010 Hack Hewlett-Packard HP iOS Jailbreak Java LinkedIn Linux Lync McAfee MSI MySQL Navigation Objects Office Outlook Passat Password PowerPoint PowerShell RES RNS315 RNS510 SasLibEx Terminal Server ThinApp TSAdminEx VBS VCDS Vista VMWare Volkswagen Windows PE Wordpress XenApp