15 Nov
I wanted to know if a certain server had a Battery Backed Write Cache module (BBWC) on it’s array controller.
I suspected it did not, but I had to be sure. Since this server was running production I couldn’t open (Visual Inspection) or reboot it.
The server didn’t have Insight Agents installed so I couldn’t query it via iLO or the Insight Agents webpage either.
I knew that when you do a full install of the array controller bundled software it comes with a commandline tool, hpacucli.exe.
28 Apr
I ran into an error when I was upgrading hardware on an HP BL460c G6 Blade.
After placing 2 new (larger) hard drives the Array Configuration would hang after saving the configuration (It just kept blinking “Saving Configuration.” forever.
After a reset the Smart Array Controller (P410) halted a very long time on Initializing and eventually failed.
I retried the whole procedure with the same result but this time the controller reported: “previous lockup code 0xAB”.
My next step would be a firmware update and this kb article from HP confirms that it was indeed a firmware issue: HP Serial Smart Array Controllers P410/411/212/712m/410i – May Hang with Lockup Error Code 0XAB Configured in Zero Memory Mode.
This kb article also tells me why I didn’t have this error on another blade: that one had the Battery Backed Write Cache module.
Active Directory Altiris Automation Manager bug Citrix Dell Delphi Exchange Exchange2003 Exchange2010 Hack Hewlett-Packard HP iOS Jailbreak Java LinkedIn Linux Lync McAfee MSI MySQL Navigation Objects Office Outlook Passat Password PowerPoint PowerShell RES RNS315 RNS510 SasLibEx Terminal Server ThinApp TSAdminEx VBS VCDS Vista VMWare Volkswagen Windows PE Wordpress XenApp